SECTION 4 – LIGHTING SYSTEM AND ELECTRICS
CONTROL
• ETC Ion
• Located 3rd Floor Technical Gallery in Lighting Booth.
• Portable Position located in rear of Orchestra Center House
• Possible Operating Positions from Backstage Left, Backstage Right and Proscenium Catwalk.
D
IMMERS
• 294 Strand CD80sv, located in 4 racks.
• Rack location in Mechanical Closet accessible from stairwell adjacent to theatre.
• 26 of these dimmers dedicated as Houselights and Stage Worklights .
C
IRCUITS
• 268 circuits with 20 amp, 3-pin stage connectors.
• Several circuit box locations equipped with breakouts.
! Grid Level
• Stage Right: DS circuits 256-267; US circuits 244-255
• Stage Left: DS circuits 184-207; MS circuits 208-231; US circuits 220-243
! Proscenium
• Stage Right: 13-15
• Stage Right Pinrail: 88-117
• Stage Left: 10-12
• Stage Left Pinrail: 1-6, 40-63
! Pinrail
• SR circuits 178-183
• SL circuits 172-177
! US Wall
• SR - 28-39
• SL - 16-27
! Catwalks
• Proscenium: 88-93 HR; 94-99 HL
• 1st Catwalk: 100-105 HR; 106-111 HC; 112-117 HL
• 2nd Catwalk: 118-123 HR; 124-129 HRC; 130-135 HC; 136-141 HLC; 142-147 HL
! Technical Gallery
• 64-75 HR Wall
• 148-159 HR Booth Rail
• 160-171 HL Booth Rail
• 76-87 HL Wall
! HR Box Position: 40-45
! HL Box Position: 58-63
! HR Alcove: 40-45
! HL Alcove: 58-63
! Balcony Rail Position: 46-57
! Trap Room
• SL - 1-6
• SR - 7-9
D
ESIGNATED ELECTRICS: - Any batten without soft goods may be used as an electric pipe (See FIG 3.3-1)
COMPANY SWITCH
• US Left: Two (2), 400 amp, 120/208 VAC, 3-phase, 4 wire, Colortran Model #6-9007
• DS Left: One (1), 100 amp, 120/208 VAC, 3-phase, 4 wire, Colortran Model #6-9008
A
DDITIONAL POWER
• Proscenium Catwalk: 60 amp, 3-phase, 240V Disconnect Strip
! one (1) 100 amp, 3-phase, 4 wire disconnect; one (1) 50 amp, 2 pole/1 pole, 3-phase, 4 wire
disconnect;
! one (1) 20 amp, 3 pole Disconnect;
! one (1) 20 amp, 1 pole disconnect
• Grid: two (2) strips, one (1) SR and one (1) SL
! one (1) 100 amp, 3-phase, 4 wire disconnect
! one (1) 50 amp, 2 pole/1 pole, 3-phase, 4 wire disconnect
! one (1) 20 amp, 3 pole Disconnect
! one (1) 20 amp, 1 pole Disconnect
• Tech Gallery Booth - one (1) 60 amp, 3-phase, 240V Disconnect
Comments to this Manuals