SECTION 4 LIGHTING SYSTEM AND ELECTRICS
CONTROL
ETC Ion
Located 3rd Floor Technical Gallery in Lighting Booth.
Portable Position located in rear of Orchestra Center House
Possible Operating Positions from Backstage Left, Backstage Right and Proscenium Catwalk.
D
IMMERS
294 Strand CD80sv, located in 4 racks.
Rack location in Mechanical Closet accessible from stairwell adjacent to theatre.
26 of these dimmers dedicated as Houselights and Stage Worklights .
C
IRCUITS
268 circuits with 20 amp, 3-pin stage connectors.
Several circuit box locations equipped with breakouts.
! Grid Level
Stage Right: DS circuits 256-267; US circuits 244-255
Stage Left: DS circuits 184-207; MS circuits 208-231; US circuits 220-243
! Proscenium
Stage Right: 13-15
Stage Right Pinrail: 88-117
Stage Left: 10-12
Stage Left Pinrail: 1-6, 40-63
! Pinrail
SR circuits 178-183
SL circuits 172-177
! US Wall
SR - 28-39
SL - 16-27
! Catwalks
Proscenium: 88-93 HR; 94-99 HL
1st Catwalk: 100-105 HR; 106-111 HC; 112-117 HL
2nd Catwalk: 118-123 HR; 124-129 HRC; 130-135 HC; 136-141 HLC; 142-147 HL
! Technical Gallery
64-75 HR Wall
148-159 HR Booth Rail
160-171 HL Booth Rail
76-87 HL Wall
! HR Box Position: 40-45
! HL Box Position: 58-63
! HR Alcove: 40-45
! HL Alcove: 58-63
! Balcony Rail Position: 46-57
! Trap Room
SL - 1-6
SR - 7-9
D
ESIGNATED ELECTRICS: - Any batten without soft goods may be used as an electric pipe (See FIG 3.3-1)
COMPANY SWITCH
US Left: Two (2), 400 amp, 120/208 VAC, 3-phase, 4 wire, Colortran Model #6-9007
DS Left: One (1), 100 amp, 120/208 VAC, 3-phase, 4 wire, Colortran Model #6-9008
A
DDITIONAL POWER
Proscenium Catwalk: 60 amp, 3-phase, 240V Disconnect Strip
! one (1) 100 amp, 3-phase, 4 wire disconnect; one (1) 50 amp, 2 pole/1 pole, 3-phase, 4 wire
disconnect;
! one (1) 20 amp, 3 pole Disconnect;
! one (1) 20 amp, 1 pole disconnect
Grid: two (2) strips, one (1) SR and one (1) SL
! one (1) 100 amp, 3-phase, 4 wire disconnect
! one (1) 50 amp, 2 pole/1 pole, 3-phase, 4 wire disconnect
! one (1) 20 amp, 3 pole Disconnect
! one (1) 20 amp, 1 pole Disconnect
Tech Gallery Booth - one (1) 60 amp, 3-phase, 240V Disconnect